Black & Decker DCM200C Installationsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
DCM 200 Installation
Page 6
Flow Switch Function
The above precaution pertains to Input ‘F’ lockouts as well as the integral flow switch on input ‘E’. If
disabled or bypassed, the sensor would not be able to sense a hazardous situation and turn of the
chemical feed pumps to prevent uncontrolled chemical feed.
Test Flow Switch Function
Chemical Feeders
NEVER OVERRIDE A FLOW SWITCH
Uncontrolled feeding of concentrated chemicals can result in personal injury
or death. Sample and recirculation flow switches are critical safety devices
which prevent uncontrolled chemical feed. Follow Instructions Carefully.
Flow switches are provided with all ProMinent pool controllers and are an
integral safety device to prevent the uncontrolled feed of chemicals, which
could cause personal injury or death. This critical safety device must always
be available to protect the swimmers and others near the pool.
Flow switches should NEVER be bypassed, even temporarily.
If flow switch
‘float’
does not
drop to the bottom
and remain
there
during no-flow, backwash, or very low flow conditions, the
controller cannot prevent the uncontrolled feed of chemicals,
which could cause personal injury or death.
Testing of the flow switch installation is essential to assure the
flow switch stops, remains stop
ped, and controller shows
“SensorFlow ALARM” within 20 seconds, whenever filter is in
backwash or circulation flow stops. If the flow switch does not fully
drop, plumbing corrections or the installation of additional
safeguards will be necessary to avoid uncontrolled chemical feed.
NEVER CONNECT FEEDER DIRECTLY TO POWER SOURCE
If the chemical feeders are connected to a wall outlet, the safety
devices integral to your ProMinent controller, and to the safe
feeding of chemicals, will be bypassed. It is very important that
the chemical feeders be connected to the controller and never
directly to a wall outlet. If the chemical feeders are connected to a
wall outlet and feeding continuously, when the flow of water to the
pool stops due to filter backwash, the circulation pump losing
prime or other causes, potentially hazardous concentrations of
chemicals can be fed into a pool or spa. Follow Instructions
carefully to insure safe operation.
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare