GasAlertMax
User Manual
Setting the Alarm Setpoints
Note
TWA, STEL, low, and high alarm setpoints are set
for each sensor in the following order: H
2
S, CO,
LEL, and O
2
.
TWA and STEL do not apply to LEL and O
2
.
The LCD first displays the TWA alarm setpoint for H
2
S.
The set up/down arrow icon lights, prompting you to input a
new TWA alarm setpoint.
6. To change the TWA alarm setpoint, press H or G
until the LCD displays the new value.
7. Press C to save the displayed value.
8. Repeat steps #5 and #6 for the remaining alarm
setpoints and the remaining sensors.
Note
If you do not press any pushbuttons within 10
seconds of entering this display, the detector
automatically retains the existing alarm setpoint.
If you change the displayed value but pause for 10
seconds before pressing C, the detector rejects
the new value. The display shows Err (error) and
the audible alarm beeps six times. The detector will
then continue to the next value.
If the detector is on the last alarm setpoint and no
pushbuttons are pressed, the detector will exit
setting the alarm setpoints.