Service center of POWTRAN technology company
My future ,drive and control
14. Multi-speed applying with I/O
interface terminal
CODE Description Range of setting Refer. value
F0.11 command source selection 1:Terminal command channel (LED ON) 1
F0.03 frequency setting source selection 6.multiple-speed frequency setting 6
F1.01 DI2 function selection Forward rotation 1
F1.02 DI3 function selection MS speed terminal 1 12
F1.03 DI4 function selection Ms speed terminal 2 13
F1.04 DI5 function selection Ms speed terminal 3 14
E1.01 MS speed 1
-100.0~100.0%
20
E1.02 MS speed 2
-100.0~100.0%
50
E1.04 MS speed 3
-100.0~100.0%
100
MS terminal relative to Ms speed table.
Parameters setting
MS1
MS2 MS3 MS4
Kommentare zu diesen Handbüchern