Replacing a Sensor or Sensor Filter
a
aa
a Warning
To avoid personal injury, use only sensors
specifically designed for the detector. See the
section, "Replacement Parts and Accessories."
Each sensor has a high degree of resistance to common
vapors and gases. A sensor will most likely clear itself if you
remove the detector to a clean environment and wait 10 to 30
minutes.
Do not expose a sensor to the vapors of inorganic solvents
(such as, paint fumes) or organic solvents.
The section “If the Detector Does Not Work” describes
problems caused by a sensor in need of calibration or
replacement.
Sensor Filter
The sensors are equipped with a replaceable filter. Check if
the Sensor Screens are dirty. Clean the filters using clean
warm water. Dry before replacing. If they are still clogged
replace the filters
You can also, use a soft brush and warm clean water to clean
the built-in sensor screens on the oxygen and Twin Tox
sensors.